CLX-2DIMU8-277

Crestron

crestron/clx-2dimu8-277av/lighting/dimmerCLXSKU CLX-2DIMU8-277
Ports
7
In · Out
5 · 3
Max power
5540 W
Heat
88 BTU/h

I/O table

One row per physical connector — connector, link, the signal flows it carries, and power.

Crestron CLX-2DIMU8-277 277V VAC 60 Hz · 5540 W max Label Dir Connector Link Signals INPUTS LINE 1 In screw-terminal-via-CL… AC N IN 1 In screw-terminal-via-CL… AC LINE 2 In screw-terminal-via-CL… AC N IN 2 In screw-terminal-via-CL… AC OUTPUTS DIM 1–8 1 Out screw-terminal-via-CL… AC DIM 1–8 2 Out screw-terminal-via-CL… AC DIM 1–8 3 Out screw-terminal-via-CL… AC DIM 1–8 4 Out screw-terminal-via-CL… AC DIM 1–8 5 Out screw-terminal-via-CL… AC DIM 1–8 6 Out screw-terminal-via-CL… AC DIM 1–8 7 Out screw-terminal-via-CL… AC DIM 1–8 8 Out screw-terminal-via-CL… AC N OUT 1–8 1 Out screw-terminal-via-CL… AC N OUT 1–8 2 Out screw-terminal-via-CL… AC N OUT 1–8 3 Out screw-terminal-via-CL… AC N OUT 1–8 4 Out screw-terminal-via-CL… AC N OUT 1–8 5 Out screw-terminal-via-CL… AC N OUT 1–8 6 Out screw-terminal-via-CL… AC N OUT 1–8 7 Out screw-terminal-via-CL… AC N OUT 1–8 8 Out screw-terminal-via-CL… AC BIDIRECTIONAL Module Interconnect 1 Bi 5-pin 0.156-inch head… cresnet Module Interconnect 2 Bi 5-pin 0.156-inch head… cresnet POWER AC Power other 277V · 60 Hz power