CLX-2DIMU8

Crestron

crestron/clx-2dimu8av/lighting/dimmerCLXSKU CLX-2DIMU8
Ports
7
In · Out
5 · 3
Max power
3840 W
Heat
121 BTU/h

I/O table

One row per physical connector — connector, link, the signal flows it carries, and power.

Crestron CLX-2DIMU8 120V VAC 60 Hz · 3840 W max Label Dir Connector Link Signals INPUTS LINE 1 In Captive screw AC LINE 2 In Captive screw AC N IN 1 In Captive screw AC N IN 2 In Captive screw AC OUTPUTS DIM 1–8 1 Out Captive screw AC DIM 1–8 2 Out Captive screw AC DIM 1–8 3 Out Captive screw AC DIM 1–8 4 Out Captive screw AC DIM 1–8 5 Out Captive screw AC DIM 1–8 6 Out Captive screw AC DIM 1–8 7 Out Captive screw AC DIM 1–8 8 Out Captive screw AC N OUT 1–8 1 Out Captive screw AC N OUT 1–8 2 Out Captive screw AC N OUT 1–8 3 Out Captive screw AC N OUT 1–8 4 Out Captive screw AC N OUT 1–8 5 Out Captive screw AC N OUT 1–8 6 Out Captive screw AC N OUT 1–8 7 Out Captive screw AC N OUT 1–8 8 Out Captive screw AC BIDIRECTIONAL Module Interconnect 1 Bi 5-pin 0.156-inch head… cresnet, contact-closure Module Interconnect 2 Bi 5-pin 0.156-inch head… cresnet, contact-closure POWER AC Power Captive screw 120V · 60 Hz power

Provenance

Generator
genie/0.1.0
Method
llm-extraction
Validation
draft
Reviewed
2026-05-30
Source documents
  • clx-2dim8.pdfretrieved 2026-05-30