IOOpenDeviceIO
← Back to registry
devicedraftODIO 0.1.0

CLSI-C6

Crestron

crestron/clsi-c6av/lighting/controlleriLux
Ports
7
In · Out
6 · 4
Max power
2400 W
Heat
8189 BTU/h

I/O table

One row per physical connector — connector, link, the signal flows it carries, and power.

Crestron CLSI-C6 220-240V VAC 50/60 Hz · 2400 W max Label Dir Connector Link Signals INPUTS HOT In Captive screw AC NEUTRAL In Captive screw AC GROUND In Captive screw AC OUTPUTS LOAD1–LOAD6 1 Out Captive screw AC LOAD1–LOAD6 2 Out Captive screw AC LOAD1–LOAD6 3 Out Captive screw AC LOAD1–LOAD6 4 Out Captive screw AC LOAD1–LOAD6 5 Out Captive screw AC LOAD1–LOAD6 6 Out Captive screw AC BIDIRECTIONAL LOCAL DEVICES Bi Phoenix other CONTROL SYSTEM Bi Phoenix other PC Bi 3.5 mm rs-232 POWER AC Power Captive screw 220-240V · 50/60 Hz power

Provenance

Generator
genie/0.1.0
Method
llm-extraction
Validation
draft
Reviewed
2026-05-30
Source documents
  • clsi-c6_1.pdfretrieved 2026-05-30