IOOpenDeviceIO
← Back to registry
devicedraftODIO 0.1.0

CLS-EXP-DIM

Crestron

crestron/cls-exp-dimav/lighting/dimmeriLux
Ports
7
In · Out
5 · 2
Heat
140 BTU/h

I/O table

One row per physical connector — connector, link, the signal flows it carries, and power.

Crestron CLS-EXP-DIM 120-277V VAC 50/60 Hz Label Dir Connector Link Signals INPUTS INPUT, CTRL In Captive screw AC INPUT, NEUT In Captive screw AC OUTPUT, HOT In Captive screw AC OUTPUT, NEUT In Captive screw AC GROUND In Captive screw AC OUTPUTS OUTPUT, DIM OUT Out Captive screw AC OUTPUT, (NC) Out Captive screw AC POWER AC Power Captive screw 120-277V · 50/60 Hz power

Provenance

Generator
genie/0.1.0
Method
llm-extraction
Validation
draft
Reviewed
2026-05-30
Source documents
  • cls-exp-dim_1.pdfretrieved 2026-05-30